HYDROX CHEMICAL CO. -- ISPROPYL RUBBING ALCOHOL 70% -- 6505-00-655-8366
=====================  Product Identification  =====================

Product ID:ISPROPYL RUBBING ALCOHOL 70%
MSDS Date:09/30/1995
FSC:6505
NIIN:00-655-8366
MSDS Number: BJVZS
=== Responsible Party ===
Company Name:HYDROX CHEMICAL CO.
Address:170 KELLY STREET
City:ELK GROVE
State:IL
ZIP:60007
Info Phone Num:(312) 981-0045
Emergency Phone Num:(312) 981-0045
CAGE:1DZ38
=== Contractor Identification ===
Company Name:HYDROX CHEMICAL CO INC
Address:825-B TOLLGATE RD
Box:City:ELGIN
State:IL
ZIP:60123
Country:US
Phone:800-255-3924/708-468-9400
CAGE:1DZ38

=============  Composition/Information on Ingredients  =============

Ingred Name:ISOPROPYL ALCOHOL  (SARA III)
CAS:67-63-0
RTECS #:NT8050000
Fraction by Wt: 70%
Other REC Limits:400 PPM
OSHA PEL:400 PPM/500 STEL
ACGIH TLV:400 PPM/500STEL;9192

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NOT GIVEN FOR PRODUCT
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:GENERALLY USED AS A RUBDOWN. VAPOR
    IRRITATES EYES. HIGH CONCENTRATION OF VAPOR CAN IRRITATE
    RESPIRATORY TRACT, MAY BE ANESTHETIC AND MAY CAUSE CNS DEPRESSION.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
    CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
    CARCINOGENS.
Effects of Overexposure:GIDDINESS, HEADACHE, DIZZINESS, NAUSEA, EYE
    IRRITATION.
Medical Cond Aggravated by Exposure:PRE-EXISTING EYE AND RESPIRATORY
    DISORDERS MAY BE AGGRAVATED BY EXPOSURE.

=======================  First Aid Measures  =======================

First Aid:INHALATION: MOVE TO FRESH AIR. INGESTION: INDUCE VOMITING AND
    CALL PHYSICIAN. EYES/SKIN: FLUSH WITH WATER. GET MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:77.0F,25.0C
Lower Limits:2 %
Upper Limits:12 %
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER FOG
Fire Fighting Procedures:DILUTION OF BURNING LIQUID W/WATER WILL EFFECT
    EXTINGUISHMENT.
Unusual Fire/Explosion Hazard:FLAMMABLE LIQUID

==================  Accidental Release Measures  ==================

Spill Release Procedures:ELIMINATE SOURCES OF IGNITION. SMALL SPILL:
    SHOULD BE FLUSHED W/LARGE AMOUNTS OF WATER. LARGE SPILLS: SHOULD BE
    COLLECTED FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT TAKE INTERNALLY. FLAMMABLE
    LIQUID. KEEP AWAY FROM HEAT, SPARKS AND OPEN FLAMES. KEEP CONTAINER
    CLOSED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:AIR SUPPLIED MASKS IN CONFINED AREAS.
Ventilation:LOCAL EXHAUST: PREFERRED. MECHANICAL: ACCEPTABLE
Protective Gloves:RUBBER, VINYL
Eye Protection:GOGGLES
Other Protective Equipment:CHEMICAL RESISTANT CLOTHING AS NECESSARY TO
    PREVENT SKIN CONTACT. AN EMERGENCY EYEWASH AND SHOWER SHOULD BE
    AVAILABLE.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
    BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
HANDLE CAREFULLY. AVOID SPILLING.

==================  Physical/Chemical Properties  ==================

HCC:F3
Boiling Pt:B.P. Text:189F,87C
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Decomp Temp:Decomp Text:NOT GIVEN
Vapor Pres: 33
Vapor Density:2.07
Spec Gravity:0.88
Evaporation Rate & Reference:2.3 (BUTYL ACETATE=1)
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID W/CHARACTERISTIC ODOR
Percent Volatiles by Volume:100%

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ANHYDRIDE, ISOCYANATE, MONOMER & ORGANO-METALLIC
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAMES, & SOURCES OF
    IGNITION.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE

====================  Disposal Considerations  ====================

Waste Disposal Methods:ATOMIZE INTO INCINERATOR IN COMPLIANCE W/LOCAL,
    STATE, & FEDERAL REGULATIONS. FLAMMABLE LIQUID.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.